How to Specify
|
Series 2000 Water & Foam Level Monitor
|
How to Specify
|
|
|
An MC Products fluid level monitor shall be supplied, consisting
of one or more sensors mounted in the tank (specify type of tanks, foam
and or water) with a display module mounted at the pump panel.
Specify tank depth & configuration (rectangular, T-tank, elliptical)
Tank prints are required for irregular shaped tanks.
The control cable connecting the units shall be RFI shielded and
have a PVC cover with Deutsch connectors.
Entire sensing unit to be constructed of non-corrosive, chemical-resistant PVC.
Electronic sensing device shall be shielded from radio
interference as well as being isolated from the fluid being
measured. Display module at pump panel will have incandescent
lamps (specify number 4 or 5) with colored lenses (specify color)
for superior visibility in direct sunlight, vertically aligned for instant
recognition of fluid level. Specify if test button is required.
|
|